Epson WF-7520/7510/7010 series Revision A
Disassembly/Reassembly Routing FFCs/cables 66
Scanner Motor Assy
When routing Scanner Motor cable and scanner grounding wire, follow
the procedure below.
1. Route the scanner grounding wire through the hooks and ribs, and
insert it into the hole of the Scanner Housing Lower.
2. Install the Scanner Motor Assy.
(p 62)
3. Route the Scanner Motor cable through the hooks and ribs, and insert
it into the hole of the Scanner Housing Lower.
After inserting the Scanner Motor cable and scanner grounding wire into
the hole of the Scanner Housing Lower, confirm the Scanner Motor cable
is over the scanner grounding wire.
Scanner
Motor
cable
Route
inside rib.
Scanner
Motor
Assy
After Scanner Motor Assy is installed
Hole of Scanner
Housing Lower
Hook
Rib
Hook
Rib
Before Scanner Motor Assy is installed
Scanner grounding wire
Hole of Scanner
Housing Lower
Route
inside rib.
Bottom of the Scanner Unit
When routing the cables/FFCs on the bottom of the Scanner Unit, follow the
procedure below.
1. Pull the Scanner FFC out from the hole A of the Scanner Housing Lower,
and secure it on the position shown above with double-sided tape.
2. Pull the Scanner Motor cable and scanner grounding wire out from the
hole B of the Scanner Housing Lower.
3. Insert the Scanner FFC into the hole 1 of the Scanner FFC Cover, and
insert the Scanner Motor cable and scanner grounding wire into the hole 2
of the Scanner FFC.
4. Install the Scanner FFC Cover to the Scanner Housing Lower.
(p 62)
Hole A
Hole B
Double-
sided tape
Before Scanner FFC Cover is installed
Scanner FFC Cover
Hole 1
Hole 2
Scanner grounding wire
Bottom of Scanner Unit
Scanner FFC Cover
Scanner FFC
When routing the Scanner FFC, follow the procedure below.
1. Fold the Scanner FFC along the fold lines and route the FFC through the rib A and along the standard line so as not to let the FFC touch the wall of the
Scanner Housing Lower, and then insert the FFC into the hole of the Scanner Housing Lower.
2. Secure the Scanner FFC on the position shown above on the Scanner Housing Lower with double-sided tape (x4).
3. Connect the Scanner FFC to the connector on the CIS Module, and secure the Scanner FFC on the position shown above on the CIS Module with double-
sided tape.
4. Install the CIS Module to the Scanner Carriage.
5. Route the Scanner FFC under the rib B (x2) of the Scanner Carriage, and confirm the FFC does not come over the guide ribs (x2) of the Scanner Carriage.
Step 1, 2
Hole of Scanner
Housing Lower
Rib A
Double-sided tape
Wall of Scanner
Housing Lower
Scanner
FFC
Standard line
Connector
CIS Module
Double-sided tape
Step 3
Scanner FFC
Rib B
Guide rib
Step 5
Scanner FFC
Scanner Housing Lower