Epson WF-7520/7510/7010 series Revision A
Disassembly/Reassembly Routing FFCs/cables 65
Main Board Unit (1)
Route the following cables as follows.
(For the correspondence between the cables, FFCs and the connectors on the Main Board, see
“ Main Board Unit (2) (p65).)
Power Supply Unit cable (CN501) Pull it out between the Grounding Plate FAX and Power Supply Unit and route it inside the rib 1 of the
Frame Base Assy, and then connect it to the connector on the Main Board.
Paper Stopper Lever Sensor 1st cable (CN26)
Route them through the hook A, hook B and hook C of the Frame Base Assy and route them inside the rib 2
Pre-PE Sensor cable (CN27) and rib 1, and then connect them to the connectors on the Main Board.
PE Sensor cable (CN15)
CR Motor cable (CN6)
PF Motor cable (CN7) Pull it out from under the Main Board Unit, and then connect it to the connector on the Main Board.
Grounding wire A Route it through the hook A, hook B and hook C and route it inside the rib 2 and rib 1 of the Frame Base
Assy, and then secure it together with the grounding wire B and Main Board Unit with the screw.
Grounding wire B Secure it together with the Frame Base Assy and Main Board Unit with the screw.
For WF-7520/7010 series, route the cables/FFCs from the 2nd Bin Base Assy as follows.
Paper Stopper Lever Sensor 2nd cable (CN29)
Route them inside the rib 3 of the Frame Base Assy and route them through the hook C and route inside the
Pickup Motor cable (CN30) rib 2 and rib 1, and then connect them to the connectors on the Main Board.
Pickup Encoder FFC (CN8) Secure it on the position shown above with double-side tape, and then connect it to the connector on the
Main Board.
Grounding wire C Route it inside the rib 3 of the Frame Base Assy and the hook C and route it inside the rib 2 and rib 1 of the
Frame Base Assy, and then secure it together with the grounding wire A and Main Board Unit with the
screw.
After connecting the Paper Stopper Lever Sensor 1st cable, Pre-PE Sensor cable, PF Motor cable, Pickup Motor cable and Paper Stopper Lever Sensor 2nd
cable to the connectors on the Main Board, insert the excess portions into the space behind the edge of the Frame Base Assy shown above.
Grounding wire A,
grounding wire C
Ferrite core
Hook A
Hook B
Hook C
Rib 3
Rib 2
Rib 1
C.B.P-TITE SCREW 3x10 F/ZN-3C (6 ± 1 kgf·cm)
Head FFC
Grounding wire B
CN11
CN12
CN13
Back
CN501
CN6
CN15
CN8
CN27
CN29
CN26
CN30
CN7
C.B.S-TITE SCREW 3x6 F/ZN-3C (6 ± 1 kgf·cm)
Edge of Frame Base Assy:
Insert excess portions behind this edge.
2nd Bin Base Assy
Hook
Double-sided tape
Rib
CN2
CN3
CN5
CN14
CN24 CN30
CN6
CN7
CN22
CN41
CN501
CN19
CN15
CN18
CN8
CN29
CN16
CN21
CN26 CN27
CN11
CN12
CN13
Back
Ferrite core130-digit side
Head FFC
Grounding wire
C.B.P-TITE SCREW 3x10 F/ZN-3C (6 ± 1 kgf·cm)
CR Unit
Head FFC
To CR Encoder
To Holder Board Assy
Front Frame
Rib
Double-sided tape
Head FFC Holder

Table of Contents