EasyManua.ls Logo

Erhardt+Leimer OL 80 - Maintenance; Technical data

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BEA--220265-EN-04 BPage31
CCDarraycameraOptoLineOL80..
Cleantheglassofthecameraprotectivecylinderandtheglass
coverofthelighttransmitterregularlywithordinarydomestic
cleaningagent.
Randomsoilingofthelighttransmitterorcameracausesincorrect
measurements.Ashomogenoussoilingbuildsup,thecameraand
lighttransmitterreceivelessandlesslightuntilthecamerabe-
comesunder-exposed.
Replacetheuorescenttubesonceayear.
Whenorderingspares,pleasespecifythelengthoftheuorescent
tubes.
Lens 1:2.8/24mm
1:2.8/28mm
1:1.8/50mm
Lensconnection M42x1,bayonet
Measuringrange dependsonlensand
distancetolens
Resolution measuringrange/8192
Scanningrate max.700Hz
Pixelfrequency 1.33MHz
Pixelcount 2048
Pixelsize 14x14µm
Activechiplength 2048x14µm=28.67mm
Spectralmaximum 500nm
Exposurecontroller 20to700Hz
Operatingfrequency 200Hz
Supplyvoltage 24VDC±15%
Powerinput 5,5W
Protectionclass max.IP65
withsuitableconnectorinserted
Operatingtemperature -10°Cto+50°C
Storagetemperature -25°Cto+80°C
DimensionsLxWxH 90x90x200mm
Housingmaterial castaluminum
Weight 1100g
12. Maintenance