BPage28 BEA--220265-EN-04
CCDarraycameraOptoLineOL80..
10. Paramter list
(Excerpt)
No. Name Default Min Max Access Description
..0. editdevice 1 1 4 R/W Selectdevicenumber,
Seeblockdiagramfordevicenumbers.
..1. editgroup 0 0 7 R/W Selectgroupnumber,
Seeblockdiagramforgroupnumbers.
..2. resetsettings 0 0 2 R/W Workssettings
0 =nofunction
1 =E+Lbasicsettings
2 =internalvaluespecication(default)
..3. startservice 0 0 199 R/W Startafunction
0 =nofunction
1 =resetguider
2 = saveparameter
3 =savestandardfunctions
4 =deneguidingcriterion(photomode)
6 = standardcalibration
7 = templatecalibration
..6. JobNumber 1 0 3 R/W Cameraoperatingmode:
"0" =nojob
"1" =contrastingedge
"2"=centerbetweentwocontrastingedges
"3"=nofunction
..7. edge1 1 -30 30 R/W Contrastingedge1:
Numberofcontrast.edgeinscanfromwhichthe
positionistobeoutput.
Thepre-signindicatesthescanningdirection:
nopre-sign=normalscanningdirection,
fromoutsidetoinside,towebcenter
negativepre-sign=oppositescanningdirection
frominsidetooutside
..8. edge2. 0 -30 30 R/W Contrastingedge2(onlyforcameramode2)
Numberofcontrast.edgeinscanfromwhichthe
positionistobeoutput.Thepre-signindicatesthe
scanningdirection,seeparameter7
..9. emergencyguidance 00 00 7F R/W Webguideremergencyguiding
0=nojob
Uneven0=addressofsensorsupplyingthe
emergencyguidingcriterion
.1.0. meas.rangestart 0 0 2047 R/W Startofmeasuringrange
Themeasuringrangestartandlengthparametersde-
termineinwhichareaofthescanvalidresults
maybesought.Ifincorrectentriesaremadeinthese
twoparameterstheentirescanningrangeisused
formeasuring(invalid:start+length>=2048pixels).
Thelimitedmeasuringrangeisalsoactiveduringcali-
bration.
.1.1. meas.rangelength 2048 10 2048 R/W Lengthofmeasuringrange(inpixels)
.1.3. offset 0 -4096 4096 R/W Offsettooutputmeasuredvalue(parameter13)
(contrastingedgesetposition)
Seetheexcerptbelowofthemostimportantcameraparameters.All
cameraparametersaredescribedintheattachedparameterlists.