Annex B
Table B.26 Suitable Signal Cable Types
Signal Type Connector Cable
Alarm Relay 9-way D-type Male
Belden 8162 CM 2PR24 shielded E108998
(typical)
ASI Out 1 and 2 BNC
Canford Audio BBC 1/3 PSF (type 2 video
cable)
ASI/SD-SDI/HD-SDI
Out 1, 2 and 3
BNC
Canford Audio BBC 1/3 PSF (type 2 video
cable)
ASI In BNC
Canford Audio BBC 1/3 PSF (type 2 video
cable)
Ethernet/IP (Gbit) RJ-45 CAT 5E Data Cable S-FTP
Audio 1 and 2 or 3
and 4
9-way D-type Male
to XLR
Canford Audio Cable DST 110
Audio 1 and 2 or 3
and 4
9-way D-type Male
to screw terminal
Canford Audio Cable DST 110
Frame Sync BNC
Canford Audio BBC 1/3 PSF (type 2 video
cable)
RF IN F - type Belden 1694A 3 GHz cable
Video Out BNC
Canford Audio BBC 1/3 PSF (type 2 video
cable)
Component Video Out
15-way D-type
Male
Five-way screened Haurtian computer
cable EL164535 ‘D’
Control 1 and 2
(100BaseT)
RJ-45 CAT 5E Data Cable S-FTP
Technical Earth 6.3 mm earthed tab Green/Yellow earth cable or similar
B.9 Compliance
7
B.9.1 Safety
This equipment has been designed and tested to meet the requirements of the
following:
EN 60950-1 European Information technology equipment - Safety.
IEC 60950-1 International Information technology equipment - Safety.
UL 60950-1 USA Information Technology Equipment - Safety.
7
The version of the standards shown is that applicable at the time of manufacture.
EN/LZT 790 0005 R1A