ESAB CUTMASTER 100
INSTALLATION 300X5397
3-4
Regulator
Input
Gas Supply
Hose
1/4 NPT to 1/4”
(6mm) Fitting
Assembly
2-Stage Filter
Inlet Port (IN)
Outlet Port
(OUT)
T
Filter
Assembly
Art # A-07945_AC
Hose Clamp
Optional Two - Stage Filter Installation
Using High Pressure Air Cylinders
When using high pressure air cylinders as the air supply:
1. Refer to the manufacturer’s specications for installation and maintenance procedures for high pressure
regulators.
2. Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign material. Briey
open each cylinder valve to blow out any dust which may be present.
3. The cylinder must be equipped with an adjustable high - pressure regulator capable of outlet pressures up
to 100 psi (6.9 bar) maximum and ows of at least 300 scfh (141.5 lpm).
4. Connect supply hose to the cylinder.
NOTE!
Pressure should be set at 100 psi (6.9 bar) at the high pressure cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm) I.D.
For a secure seal, apply thread sealant to the tting threads, according to manufacturer's
instructions. Do Not use Teon tape as a thread sealer, as small particles of the tape may
break off and block the small air passages in the torch.