EasyManua.ls Logo

ESAB ESP-200 - 3.5.2 PT-26 Torch Output Connection Procedure

ESAB ESP-200
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
SECTION 3 INSTALLATION
3.5.2 PT-26 Torch Output Connection Procedure
ELECTRIC SHOCK CAN KILL!
TURN OFF PRIMARY INPUT POWER AT THE WALL DISCONNECT BOX
BEFORE MAKING ANY CONNECTIONS TO THE ESP200.
WARNING
PT-26 Plasmarc Torches
Both hand and mechanized torches connect the same. The mechanized
torch requires an auxiliary arc ON switch that connects the same as the
arc ON switch of the hand held torch.
Note: Tighten all gas and water ttings during assembly.
1. Thread 4 torch service lines through the bushing at middle right
side of front panel and proceed as follows:
a. Insert pilot arc adapter into left hand threaded pilot arc tting.
b. Connect coolant return hose (male left-hand thread) to the
adapter.
Thread service
lines through
bushing.
Pilot arc tting
Pilot arc adapter
(P/N 999278)
c. Connect pilot arc cable to one of 3 threaded holes on the out-
side of adapter with supplied screw.
Pilot Arc Cable
d. Connect coolant supply/power cable to tting labeled
TORCH”.
Coolant Supply/electrode
cable connection
Coolant Supply/electrode
cable Fitting