8 EVENT CODES
0463 772 001
- 30 -
© ESAB AB 2023
For 406 and 206 - Return coolant temperature warning/error and Overtemperature, perform the
following actions:
1. Make sure that the cooling air inlets or outlets are not blocked or clogged by dirt.
2. Check the duty cycle being used, to make sure that the equipment is not being overloaded.
3. Wait until the temperature cools down.
For 306 - High wire motor temperature warning/error, perform the following actions:
4. Check the liner, clean using pressurized air. Replace the liner if damaged or worn out.
5. Check the wire pressure setting and adjust if needed.
6. Check the drive rolls for wear and replace if needed.
7. Make sure the filler metal spool can rotate without much resistance. Adjust the brake hub if
needed.
8. Restart the system.
9. If the error persists, check the liner, clean using pressurized air and replace the liner if damaged
or worn out.
10. If the error persists despite performing these actions, try replacing the torch.
x08
Battery warning
This event code is displayed due to one of the following:
• 208 - RTC/SRAM battery low warning.
1. Make sure that the polarity (+, - terminals) of the battery is right.
2. Contact authorised service technician to replace the battery.
x09
Internal voltage error
This event code is displayed due to one of the following:
• 209 - Internal over/under voltage error.
1. Restart the system.
2. Contact authorised person to check the main inputs.
x11
Wire feed speed fault
This event code is displayed due to one of the following:
• 311 - Wire saturation warning/error.
• 311 - Wire motor start/work current error.
1. Check the correct liners/contact tip/torch used for types of welding wires.
2. Check the torque tension in the break hub.
3. Make sure that the wire feed speed control is dust free and rotate.
4. Acknowledge by pressing any buttons on the control panel.
5. Contact service technician to check drive motor.
x14
Communication fault
This event code is displayed due to one of the following:
• 114 - Weld control communication error.
• 114 - Internal communication warning.
• 114 - Connection to main control lost.
• 114 - Fieldbus interface lost.