8 EVENT CODES
0463 772 001
- 32 -
© ESAB AB 2023
x20
User management fault
This event code is displayed due to one of the following:
• 020 - No valid job available.
1. Make sure that the predefined jobs are saved by admin.
x25
Incompatible units
This event code is displayed due to one of the following:
• 025 - System communication version mismatch warning/error.
• 025 - Power converter control module version not valid.
• 025 - Power converter control module power capacity unknown.
1. Contact service technician.
2. Make sure that the software version should be similar for each connected nodes.
3. Connect the correct wire feed unit and restart.
x26
Timing fault
This event code is displayed due to one of the following:
• 026 - Watchdog timeout.
• 026 - Process control error.
1. Restart the system (recycle power).
2. Acknowledge by pressing any buttons on the control panel.
3. Contact service technician.
x29
No coolant flow
This event code is displayed due to one of the following:
• 429 - ELP off during welding.
1. Check the coolant hose connections and acknowledge.
x31
Gas pressure fault
This event code is displayed due to one of the following:
• 631 - Gas input pressure warning/error.
1. Check gas input pressure.
2. Select the appropriate setting of gas flow in control panel.
3. Acknowledge by pressing any buttons on the control panel.
4. Contact service technician.
x32
Gas flow fault
This event code is displayed due to one of the following:
• 632 - Gas saturation warning/error.
• 632 - No gas out error.