6
NOTE: To ensure the best quality, longevity, and warranty status, these units should be cleaned daily.
1. Add blind fi lter cap (backfl ush disk) to
portafi lter (Part #236BFDISK)
2. Add detergent (Urnex 12-ESP20) and install
portafi lter
3. Press bu on 1 and 5 simultaneously to start
fl ushing (Fig. 8)
4. Bu ons 2 and 4 will light up (Fig. 9); automa c
reverse fl ushing will start and run for 10
cleaning cycles
5. To stop the reverse fl ushing before 10 cycles,
press bu on 3 (Fig. 10)
6. Each group head should be cleaned this way
7. Turn power switch off (Fig. 11)
8. Turn off water supply to machine
9. Turn all steam wand knobs to open
and leave them open to release
pressure from inside boiler tank
(Fig. 12)
10. Remove drain pan and grate
11. Open drain valve (Fig. 13), red lever
should be parallel with drain line,
leave drain valve open to completely
empty the tank
12. Wipe down machine as needed to
remove le over coff ee grounds
and milk
13. Disassemble portafi lter by gently
prying fi lter cup from fi lter holder
14. Soak portafi lter in detergent
End of Day Cleaning
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 13
Fig. 12
OFF ON
Reverse Flushing
NOTE: Shuম ng down and draining the boiler will prolong its lifespan
PREVENTATIVE MAINTENANCE