ProNet Plus Series AC Servo User's Manual
Indicates the output torque (current) of motor is limited.
Not including this setting in
the default setting,please
choose terminal output by
setting parameter Pn511
Motor output torque under limit (Internal
torque reference is higher than setting
value).
No torque limit (Internal torque reference
is lower than setting value).
Please use the following user constants to define output signals and pins when using /CLT signal.
In the case of ProNet-□□□MG servo drives, the/CLT signal is
output fromCN1-11, 12.
In the case of ProNet-□□□EG-EC servo drives, there is no
output.
In the case of ProNet-□□□MG servo drives, the/CLT signal is
output fromCN1-05, 06.
In the case of ProNet-□□□EG-EC servo drives, the/CLT signal
is output fromCN1-11, 14.
In the case of ProNet-□□□MG servo drives, the/CLT signal is
output fromCN1-09, 10.
In the case of ProNet-□□□EG-EC servo drives, the/CLT signal
is output fromCN1-13, 14.
4.11.8 Torque Detection Output(/TCR)
Not including this setting in
the default setting,please
choose terminal output by
setting parameter Pn511
Motor output torque is higher than Pn529
setting value.
Motor output torque is lower than Pn529
setting value.
Torque detection output time is set by Pn530.
/CLT
Torque limit
output
Pn511.0=3
CN1-11,CN1-12
Pn511.1=3
CN1-05,CN1-06
Pn511.2=3
CN1-09,CN1-10
Output terminal