ProNet Plus Series AC Servo User's Manual
Connect frame to ground if the shield wire of the
I/O signal cable is connected to the connector shell.
Speed coincidence:
Detects whether the motor speed is within the setting range and
if it matches the reference speed value.
Positioning completion:
Turns ON when the number of positional error pulses reaches
the value set. The setting is the number of positional error pulses
set in the reference units.
Reserved terminals:
The functions allocated to /TGON, /S-RDY, and /V-CMP (/COIN)
can be changed by using the parameters.
/CLT:Torque limit output
Turns on when it reaches the value set.
/BK:Brake interlock output
Releases the brake when ON,
/PGC: C pulse output
OT: Over travel signal output
/RD: Servo enabled motor excitation output
/HOME: Home completion output
4,18,19,29,35
36,37,38,43
44,45,47,49
The output signals description of ProNet-□□□EG-EC servo drives is as shown in the following table.
Detects when the servomotor is rotating at a speed higher than
the motor speed seeting.
Servo alarm:
Turns off when an error is detected.
Servo ready:
ON if there is no servo alarm when the control/main circuit power
supply is turned ON.
Connect frame to ground if the shield wire of the
I/O signal cable is connected to the connector shell.
Reserved terminals:
The functions allocated to /TGON and /S-RDY can be changed
by using the parameters.
/CLT:Torque limit output
Turns on when it reaches the value set.
/BK:Brake interlock output
Releases the brake when ON,
OT: Over travel signal output
/RD: Servo enabled motor excitation output