BM04101 Molift Quick Raiser English - Rev F/ 09/2012 Page 16 of 20
Troubleshooting
Below you will nd a table with fault nding pro-
cedures to identify and correct faults on the lifter:
Symptom Possible cause/action
Lifting column is
wobbly
Locking bolts are not properly
secured or lifting column is not
properly in place in the chassis
/ check if the column is correct-
ly placed in the chassis and/or
tighten bolts
Lifter only moves
one way (up or
down) / legs only
moves one way (in
or out)
Fault on hand control / exchange
with alterative control from other
lifter and/or new hand control
One of the relays / electronics
has failed/ exchange the control
unit/relays / contact your local
service representative
The lifter moves up
and/or down by it-
self / legs move by
themselves
Short circuit between the hand
control and lifter / clean the con-
nectors of the hand control and
chassis with spirits to remove
grease and dirt
The hand control has failed/ ex-
change hand control / contact
your local service representative
Relays/electronics malfunctions
/ exchange electronics/relays /
contact your local service repre-
sentative
The lifting arm
does not move
/ legs does not
move
Discharged battery / exchange
battery with another or charge
battery
Bad or wobbly connection from
lifting column to chassis / clean
contacts in column base and in-
side chassis - adjust and tighten
column bolts
Emergency stop activated / turn
clock wise to reset
Hand control disconnected / re-
connect hand control
The hand control has failed/ ex-
change hand control / contact
your local service representative
Relays/electronics malfunctions
/ exchange electronics/relays /
contact your local service repre-
sentative
Motor has failed / exchange mo-
tor / contact your local service
representative
If you have access to more than one lifter, it may
be helpful to change parts across lifters to help
identify any faults. For instance, if you suspect the
fault to be inside the column, exchange the col-
umn with at functional one from the other lifter to
see if the problem is xed.
If you are not able to solve the fault or problems
by yourself using this manual, please contact lo-
cal authorised service representative. If you do
not know whom to contact locally, please contact
your dealer or Etac Supply Gjøvik to get help.