7
2119167-06-10/20 (Translation of the original operating instructions)
Operating Instructions Safety Systems
MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
EN
Important!
Ì The user is responsible for the proper integration of the device into a safe overall system. For this
purpose, the overall system must be validated, e.g. in accordance with ENISO13849-2.
Ì Correct use requires observing the permissible operating parameters (see chapter 14. Technical
data on page 36).
Ì If a data sheet is included with the product, the information on the data sheet applies.
Table 1: Possible combinations for MGB components
Evaluation unit
Handle module
MGB-H-...
from V2.0.0
MGB…AR/AP
from V3.0.0
Key to symbols Combination possible
2.1. Main differences between MGB-AP and MGB-AR
System family Symbol Use
MGB-AP
AP
Optimized for operation in safe control systems.
If series connection is not necessary, the number of terminals required can be reduced using this system family.
MGB-AR
AR
Linking of several guards on one shutdown path. As a consequence several safety doors can be very simply polled using one evalua-
tion unit or two control system inputs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EUCHNER MGB-L1-APA-AP4A1-S1-R-158117 and is the answer not in the manual?

EUCHNER MGB-L1-APA-AP4A1-S1-R-158117 Specifications

General IconGeneral
BrandEUCHNER
ModelMGB-L1-APA-AP4A1-S1-R-158117
CategorySafety Equipment
LanguageEnglish

Related product manuals