60
Manufacturer Model Rated Primary Current (in A RMS) Turn ratio
Nidec C-CT-10 60 3.000 : 1
Nidec C-CT-16 100 3.000 : 1
Nidec C-CT-24 200 3.000 : 1
LEM TT 50-SD 50 3.000 : 1
LEM TT 100-SD 100 3.000 : 1
VAC E4623-X002 40 2.500 : 1
VAC E4624-X002 60 2.500 : 1
VAC E4626-X002 100 2.500 : 1
English
Hereafter an overview of the parameters of the control system of the Audi Wallbox is
provided. These dates can be used to evaluate whether the Overload Protection meets the
requirements that might need to be considered during the design of an installation.
¹ Already considered by the Audi Wallbox's control, unless communicated otherwise.
² In accordance to IEC 61851
Parameter Value
Sample Rate of Facility Current 10 Hz
Measurement Accuracy of Facility Current 0,1 A
max. relative Measurement Deviation of Audi Wallbox's
Control System¹
6 %
Calculation Rate of max. Charging Current 2 Hz
Accuracy of max. Charging Current 0,1 A
Update Cycle of max. Charging Current 5 s ²