64
English
CT coil / HEMS
charging paused
Charging not possible
The house power consumption is too
high to permit charging. The wallbox
starts charging again when power
becomes available.
CT coil / HEMS
derating
Charging possible
When the house power consumption is
high, the wallbox allows charging only
at a lower power. Once the house pow-
er consumption is normal, the wallbox
allows charging at maximum power.
CT coil / HEMS
without derating
Charging possible
When the house power consumption
is normal / usual, the wallbox allows
charging at maximum power.
Loss of
communication
with HEMS
Charging possible
The wallbox is unable to communicate
with the HEMS network.
› Using the Conguration Manager,
check your network conguration.
› Using the Conguration Manager,
check your HEMS conguration.
Self-test failure or
processor freeze
Charging not possible
The wallbox has detected an internal
error during a self-test.
› Have the wallbox switched o at the
power supply cabinet. Have the wall-
box switched on again for a reboot.
› If the error remains, have the HMI ca-
ble checked for a proper connection.