8
Care and Cleaning
CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and
allow time for it to cool after periods of extended use.
Do
Do Not
When the power is disconnected, inspect the pump suction
screen and remove all debris, then plug the pump back into
the grounded (GFCI) outlet.
Do not disassemble the motor housing. This motor has NO
repairable internal parts, and disassembly may cause
leakage or dangerous electrical wiring issues.
Do not lift up the pump by the power cord.
To clean a pump clogged with debris:
Unplug the pump from electrical power.
Remove debris from the bottom plate(6).
Remove the screws (7) and bottom plate (6), remove the screws (5) and take out the volute (4) from the pump and clean the debris on
the shaft (1)and impeller (3).
Reassemble the volute (4) and bottom plate (6).