99
Raw Water System
CAUTION
SHOULD A HOSE RUPTURE, TURN THE PUMP OFF
IMMEDIATELY. ALWAYS CLOSE THE THRU-HULL VALVE
WHEN PERFORMING MAINTENANCE ON A RAW WATER
SYSTEM.
THE BATTERIES MUST BE PROPERLY CHARGED.
OPERATING ANY PUMPS FROM A BATTERY WITH A LOW
CHARGE MAY LEAD TO A PUMP FAILURE.
THE RAW WATER SYSTEM MUST BE PROPERLY WINTERIZED
PRIOR TO WINTER LAY-UP. SEE SECTION ON WINTERIZING.
Cleaning the Seakeeper Pump Strainer
Periodically clean the Seakeeper pump sea strainer
using the following procedure.
Turn o the Seakeeper and deactivate the Sea-
keeper circuit breaker.
Close the valve at the intake seacock.
Turn the strainer bowl counterclockwise to re-
move it and remove the screen.
Thoroughly ush the screen and the inside of the
strainer bowl to remove foreign matter.
Lubricate the O-ring lightly with silicon or Tef-
lon grease and reinstall the strainer bowl.
Reassemble the strainer making sure that the
bowl is tight.
Open the intake valve, activate the Seakeeper
and check for leaks and proper water ow.
Typical Seakeeper System Sea Strainer