Design and function
MIG/MAG welding
36
099-005221-EW501
05.09.2016
Non-latched mode
Figure 5-16
Step 1
Press and hold torch trigger.
Shielding gas is expelled (gas pre-flows).
Wire feed motor runs at “creep speed”.
Arc ignites after the wire electrode makes contact with the workpiece; welding current flows.
Change over to pre-selected wire speed.
Step 2
Release torch trigger.
WF motor stops.
Arc is extinguished after the preselected wire burn-back time expires.
Gas post-flow time elapses.