040112XX
EXCELL PRECISION CO., LTD
ZSME400000004
75
Function code 06: Modbus (41026): write batch finish delay time write
Name
Input
Description
Name
Output
Description
ID Address
01
Machine ID
ID Address
01
Machine ID
Function
code
06
Function
code
06
Register's
address
04
Batch Finish delay
time address
1026
(10)
= 04 02
(HEX)
Register's
address
04
Batch Finish delay
time address
1026
(10)
= 04 02
(HEX)
02
02
Setting
value
00
Input value 7s
is 0007
(HEX)
Setting
value
00
Input value 7s
is 0007
(HEX)
07
07
CRC
xx
CRC
xx
xx
xx
Function code 01: Modbus (00000~00001): read current scale status
Name
Input
Description
Name
Output
Description
ID Address
01
Machine ID
ID Address
01
Machine ID
Function
code
01
Function
code
01
Register's
address
00
Starting Address
Bit
02
Read 2 Bit data:
2=10
(2)
, 00001 = 1
(return to zero) or 0
(non return to zero),
00000 = 0 (stable) or
1 (unstable)
00
Setting
value
00
Read 2 status (2 Bit)
00000~00001
02
CRC
BD
CRC
D0
CB
49