EXE RISE D8 - Technical Data

EXE RISE D8
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36 / 64
3.5 TECHNICAL DATA
- 4 x 1.5 mm
2
power cable fitted with CEE 16A 6h 400VAC 3PH +G black plug.
- 4 x 1.5 mm
2
control cable fitted with CEE 16A 4h 24VAC 3PH +G black plug (LVC only).
- Internal 25VA transformer: 400VAC on the primary windings, and 24VAC on the secondary
windings.
- Delay fuse 100 mA (0.1 A) on the primary windings, and rapid fuse 1 A on the secondary windings.
- Three-pole Schneider Electric series LC2-K09 reversing contactors with 24 V AC coil for a rated
power of 4 kW (AC3/400V).
- Mechanical limit switch 4 position with manual cam adjustment.
- Maximum control (Low Voltage Control) cable length attachable to motor: 50 m.
- Maximum chain length managed by low voltage control hoist: 60 m for single fall models and 30 m
for double fall models.
Other voltages and frequency are available on request.
For fully markets the chain hoist configuration available is 208VAC - 3 @ 60Hz. Custom configuration are
also possible, please refer to your local EXE TECHNOLOGY representative for all information.