POWER SUPPLY OPTIONS
A.
Internal Rechargeable Battery
Type: 2 "D" cells, 1.25 V NiCd.
Operation time: Typically 8 hours of operation at 25
o
C, no backlight, 4 AH NiCd.
Charging: External, constant current float charger, overnight charging,
full charge indication by LED.
B. Internal Battery
Type: 2 "D" cells, alkaline.
Battery Life: Typically 15 hours of operation at 25
o
C, no backlight,
with Alkaline EVEREADY #1250.
C. External
:
Type: 12 VDC, 1.0A external power supply
Voltage Range: From 9-24VDC.
CONNECTORS
Charger (Ext. Power Supply): 2.5 mm power circular jack, "+" on the center pin.
Mating connector: 2.5 mm power circular plug.
Serial Channel: 3.5 mm stereo jack.
Mating connector: 3.5 mm stereo plug.
Docking Station: 4 spring loaded pins for power and RS232
PHYSICAL
Dimensions: L = 9.25" (235 mm)
W = 4.5" (110 mm)
H = 3.9" (100 mm), 6.75" (170 mm) including handle
Weight: 1.9 kg ( 4.4 lbs) without battery.
2.4 kg ( 5.5 lbs) including battery.
ENVIRONMENTAL
Operating Temperature Range: - 10 to + 50
o
C
Storage Temperature Range: - 20 to + 60
o
C
Protection: Weather proof , dust and water sealed (no immersing).
Non-condensing Relative Humidity: Less than 90% at 40
o
C.
Vibration: 0.5G max. (10 - 300 Hz, XYZ directions, 1 h)
Shock: 3G (10 mS, XYZ directions, 1 time each).
RFI/EMI Emission: Complies with FCC rules (47 CFR Part 15) for class A.
Full CE Certification