26
Rosetta
Capsule Group
Programming the coffee dosage
Programming the hot water dosage
PROGRAMMING
i
This section explains how to program the doses dispensed automatically by the drink buttons.
Note:
Programming any of the options on the left-hand Drink buttons (when viewing the
machine from the front) automatically sets the dispensing volumes on all of the other
Drink buttonss. This only applies to the left-hand Drink buttons. Programming other
Drink buttonss only modifies the option selected.
Important:
Use a porta-filter filled with fresh coffee for every new dose you program.
On machines not equipped with a display, hold down the Continuous Dispensing button for
4 seconds. On machines equipped with a display, hold down the Continuous Dispensing button for 8
seconds. The Continuous Dispensing button light will flash. On machines equipped with a display, all
of the Drink buttons lights will be turned on.
Press the dispensing option that you wish to program: 1 Short Espresso, 1 Long Espresso, 2 Short
Espressos or 2 Long Espressos. The lights on the button pressed and on the Continuous Dispensing
button will remain on.
The group will start dispensing coffee. When the desired volume is reached in the cup, press the
selected button again to stop dispensing. This volume setting will be saved. On machines equipped with
a display, the lights on the reprogrammed dosage buttons will remain off.
Repeat this process for all of the dispensing options that you wish to reprogram.
If you only need to reprogram one of the dispensing options, follow the steps above and program just
that option. All of the other dispensing options will remain unchanged (default settings).
This function is only available in models equipped with an automatic water lever.
Press the Continuous Dispensing button and hold it down for 8 seconds. The Continuous
Dispensing button light will flash and all of the lights on the button panel will be turned on.
Briefly press the Continuous Dispensing button . The water lever will start dispensing hot
water.
Press the button again to stop dispensing hot water. The new dose setting will be saved.
Each button panel can be programmed with different doses (note that the left-hand button panel will
always override the others).