CHAPTER 12
PAGE 12
MAINTENANCE MANUAL EXTRA 300/SC
PAGE DATE: 1. August 2014
9 Slowly pump clean hydraulic fluid in the system. Bleeding
should continue until no more air bubbles are expelled from
the system (observe the immersed end of the clear hose),
and a firm brake pedal is obtained (fill each side of the sys-
tem with min. 0.33 ltr (0.1 U.S. Gallons) for complete
change). Fill the fluid reservoir up to full reservoir capac-
ity.
10 Reinstall fluid reservoir filler plug.
11 Close bleeder fitting.
12 Disconnect the connector hose.
13 Reinstall bleeder fitting cap.
14 Check the brake operation.
15 Reinstall engine cowlings as per Chapter 71-10-00.
12-10-07 Tire Inflation
For the EXTRA 300/SC the required tire pressure is 2620 hPa
(38 Psi) for both main wheels. Use regulated air pressure to