MAINTENANCE MANUAL EXTRA 300/SC
CHAPTER 05
PAGE 38
PAGE DATE: 1. August 2014
UNSCHEDULED MAINTENANCE CHECKS
05-50-03 Engine Fire
After an engine fire, perform a check as described in the
following:
For damage evaluation consult the manufacturer, before the
aircraft is put back into service.
O 1 Check all cables and hoses, replace when necessary
O 2 Check engine according to the Lycoming Manual
O 3 Check fire wall and engine cowling for damage by high temperatures
(e.g. signs of blisters on the protective paint) If necessary renew LJF
PR 812 seals. Protective paint does not need to be reapplied.
05-50-04 Lightning Strike
In the event of a lightning strike in flight or on ground check
the following:
O 1 Check engine according to Lycoming Service Bulletin 401.
O 2 Check the skin of the strike area for burns and melting
O 3 Inspect bolts and fasteneners for burns and melting .
O 4 Check the electrical system, with running engine, for correct opera-
tion.
O 5 Check the avionic and antenna for correct operation.
O 6 Check the magnetic compass for correct readings.
O 7 Overhaul Magnetos according to Magneto Maintenance and Overhaul
Manual (See Chapter 01).
Inspector:
Mechanic:
Inspections
Date:
Serial No.:
Inspector:
Mechanic:
Inspections
Date:
Serial No.: