PAGE DATE: 16. June 2008
Oil temperature is limited by installation of a single oil
cooler.
Ignition is a magneto type with 2 independent systems.
The complete power plant is attached to the fuselage struc-
ture using 4 mounting points and rubber vibration absorbers.
I M P O R T A N T If replacement of the engine control cables is neces-
sary, renew the sealing of the bushing grooves and gaps
at the engine side of the firewall. Use PRC-812 (Prod-
ucts Research & Chemical Corporation, USA) firewall
sealant. Cover the control cables with AEROQUIP
AE102-6 Fire sleeves inside the engine department.