ELISIR PRODUCT DISPLAY TABLES
27
Chapter 9
LUMINOUS INDICATORS
Signals
Explanation
Display
Crono
Indicator on = Chrono on
Indicator o = Chrono o
Room temperature
On = Room temperature lower to wanted set
O = Room temperature higher to wanted set
stby
O = Stby deactivated
On = Stby activated
Ign-plug
O = electrode active
On = electrode deactivated
To restore the functioning of the component, contact an
authorised technician.
fumes motor.
O = fumes motor not working
On = fumes motor working
Flashing = contact an authorised technician.
Pellet load motor reducer
On = working
O = not working
tangential fan
O = not working
On = working
Ducting fan
O = not working
On = working
Flashing = motor at minimum (input in additional heat board
open)
State of input STBY
O = contact open
On = contact closed
Additional thermostat state of input
O = contact open
On = contact closed
Feed-box probe
O = normal functioning
Flashing = anomaly
It indicates the communication
between remote control and stove.
Every time a key is pressed on the remote control the indicator
must switch on.
If the indicator is always on it indicates that the communication
between remote control and stove is blocked.
To restore the functioning of the component, contact an
authorised technician.