Chapter 6: Installing Summit Family Switches
Summit Family Switches Hardware Installation Guide
252
3 Verify that the power supply is right side up (see Figure 193 and Figure 194).
4 Carefully slide the power supply all the way into the power supply bay (see Figure 193 and
Figure 194). Push the power supply in until the latch snaps into place.
CAUTION
Do not slam the power supply into the switch.
To install a second power supply, repeat steps 2 through 4.
Connecting the Ground Cable
WARNING!
Be sure to connect the chassis ground wire before you connect any power cables.
Be sure to disconnect the ground wire after you disconnect all power cables.
To connect the ground wire:
1 Verify that the DC circuit is de-energized.
2 Attach an ESD-preventive wrist strap to your bare wrist and connect the metal end to an appropriate
ground point on the rack.
3 Identify the grounding point on the front panel of the power supply (see Figure ).
4 Insert a a 6-32 UNC screw (provided) through the ring terminal and into the grounding point on
the power supply.
5 Tighten the screw to 12.6 inch-pounds (1.42 Newton-meters).
Figure 193: Installing a Summit 300 W DC
Power Supply (Model 10934A)
Figure 194: Installing a Summit 300 W DC
Power Supply (Model 10933)
SH_208