Replacing DC Power Supplies in Summit Family Switches
Summit Family Switches Hardware Installation Guide
302
To connect the DC power cables to the Summit 450 W DC power supply:
1 Verify that the DC circuit is de-energized.
2 Connect the DC power input cables as follows:
a On each terminal, loosen the screw enough to allow the spade terminal to slide underneath the
captive square washer (
Figure 254).
b Slide the spade terminal of the negative wire (–48 V) under the captive square washer on the
negative terminal (labeled ).
c Slide the spade terminal of the positive wire (–48 V RTN) under the captive square washer on the
positive terminal (labeled +).
Figure 249: Connecting the DC Power Cables (Part 1)
d Tighten both screws on the terminal block to 7 inch-pounds (0.99 Newton meters) (
Figure 250).
SH_161
(+)
(–)
RTN
-48V

Table of Contents

Other manuals for Extreme Networks Summit X460-48t

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks Summit X460-48t and is the answer not in the manual?

Extreme Networks Summit X460-48t Specifications

General IconGeneral
BrandExtreme Networks
ModelSummit X460-48t
CategorySwitch
LanguageEnglish

Related product manuals