EasyManua.ls Logo

FAAC A1400 AIR RD - 14 System Functionality;Configurations; Operating Mode

FAAC A1400 AIR RD
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A1400 AIR RDT 68 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
14. SYSTEM FUNCTIONALITY/CONFIGURATIONS
14.1 OPERATING MODE
The following operating modes may be activated from SDK EVO :
Selection is carried out by pressing the keys on the fixed part of the
programmer; the function is identified by the corresponding symbol
switching on.
- NIGHT
The door closes and motor block is activated (if present). The internal
and external radar are disabled.
The Key control causes opening and closing again after the night-
time pause time.
- MANUAL
The sliding leaves are free and may be manually operated.
The door does NOT operate as an escape route in NIGHT-TIME and
MANUAL modes.
- AUTOMATIC

The door opens (partially or totally) then closes again after the set
pause time (default 2 sec.).
Pause time adjustment from 0 to 30 sec.
- DOOR OPEN
The door opens and remains open.
- TWO-DIRECTION AUTOMATIC
Pedestrian transit occurs in both directions; the internal and external
radars are enabled.
- ONE-DIRECTION AUTOMATIC
Pedestrian transit occurs in one direction only; the external radar is
disabled.
- TOTAL OPENING
100%
The door opens fully.
- PARTIAL OPEN
%
The door performs reduced openings (default 20%).
Adjustment from 20% to 95% of total opening with 5% step.
Function Door Status Internal Sensor External Sensor KEY Emergency
MANUAL
-------- no effect no effect no effect no effect
TOTALLY OPEN
100%
OPEN no effect no effect no effect no effect
AUTOMATIC TWO-DIRECTIONAL
TOTAL

100%
OPEN pause counting restarts pause counting restarts pause counting restarts no effect
CLOSED
total opening and closure again
after pause time
total opening and closure again
after pause time
total opening and closure again
after pause time
total opening
AUTOMATIC TWO-DIRECTIONAL
PARTIAL

%
OPENING
PARTIAL
pause counting restarts pause counting restarts pause counting restarts total opening
CLOSED
partial opening and closure again
after pause time
partial opening and closure again
after pause time
partial opening and closure again
after pause time
total opening
AUTOMATIC ONE-DIRECTIONAL
TOTAL (EXIT ONLY)

100%
OPEN pause counting restarts no effect pause counting restarts total opening
CLOSED
total opening and closure again
after pause time
no effect
total opening and closure again
after pause time
total opening
AUTOMATIC ONE-DIRECTIONAL
PARTIAL (EXIT ONLY)

%
OPENING
PARTIAL
pause counting restarts no effect pause counting restarts total opening
CLOSED
partial opening and closure again
after pause time
no effect
partial opening and closure again
after pause time
total opening
NIGHT
CLOSED no effect no effect
total opening and closure again
after night pause time
total opening
PARTIAL NIGHT-TIME
%
CLOSED no effect no effect
partial opening and closure again
after night pause time
total opening
PARTIAL OPENING
%
OPEN
PARTIAL
no effect no effect no effect no effect

Table of Contents