“EXPERT” CONFIGURATION 10 sec
Display Function Setting
01
If this function is activated, automatic closing occurs after the pause time.
Y = automatic closing
no = disabled
02
If this function is activated, two distinct input operation mode is obtained: OPEN for opening
and CLOSED for closing.
Y = 2-input operation
no = disabled
03
Activation of recognition of the OPEN and CLOSE input levels (maintained command).
That is to say, the board recognises the level (if, for example, with OPEN held, you press
STOP, when the latter is released, the automated system will continue to open). If
03 is disa-
bled the board commands a manoeuvre only if there is an input variation.
Y = level recognition
no = status variation
recognition
04
Activation of DEAD-MAN opening (command always pressed). Releasing the OPEN command
will stop operation
Y = active
no = disabled
05
When this function is activated, the OPEN command during opening will stop movement. If
parameter
06 is no the system is ready for opening.
If parameter
06 is Y the system is ready for closing.
Y = when opening it stops
no = disabled
06
When this function is activated, the OPEN command during opening reverses movement. If
parameters
05 and 06 are no OPEN will have no effect during opening.
Y = when opening it reverses
no = disabled
07
When this function is activated, the OPEN command during pause stops operation.
If parameters
07 and 08 are no OPEN resets the pause time
Y = when in pause it stops
no = disabled
08
When this function is activated, the OPEN command during pause causes closing.
If parameters
07 and 08 are no OPEN resets the pause time.
Y = when in pause it closes
no = disabled
09
When this function is activated, the OPEN command during closing stops operation,
otherwise it reverses movement.
Y = stops
no = reverses
10
Activation of DEAD-MAN closing (command always pressed). Releasing the CLOSE command
will stop operation
Y = active
no = disabled
11
When this function is activated, the CLOSE command has priority over OPEN, otherwise
OPEN has priority over CLOSE.
Y = active
no = disabled
12
When this function is activated, the CLOSE command commands closing when released. As
long as CLOSE is activated, the unit stays in closing pre-fl ashing.
Y = closes when released
no = closes immediately
13
When this function is activated, the CLOSE command during opening stops operation, other-
wise the CLOSE command commands reverse immediately or when opening is completed
(see also parameter
14)
Y =
CLOSE stops
no = CLOSE reverses
14
When this function is activated, and if parameter 13 is no, the CLOSE command commands
immediate closing at the end of the opening cycle (stores CLOSE). If parameters
13 and 14
are no CLOSE commands immediate closing.
Y = closes at the end of
opening
no = immediate closing
15
When this function is activated, with the system blocked by a STOP, a next OPEN
moves in the opposite direction. If parameter
15 is no it always closes.
Y = moves in the opposite
direction
no = always closes
16
When this function is activated, during closing, the CLOSING SAFETIES stop and allow motion
to resume when they are disengaged, otherwise they immediately reverse opening.
Y = closes when disengaged
no = immediate reverse
17
When this function is activated, the CLOSING SAFETIES command closing when they are
disengaged (see also parameter
18).
Y =
closing when FSW
is disengaged
no = disabled
18
When this function is activated, and if parameter 17 is Y, the unit will wait for the
opening cycle to end before executing the closing command provided by the
CLOSING SAFETIES.
Y = closes at the end of
opening
no = disabled
19
When this function is activated, during closing, LOOP2 stops and allows motion to resume
when it is disengaged, otherwise it immediately reverses opening.
Y = closes when disengaged
no = immediate reverse
20
When this function is activated, LOOP2 commands closing when it is disengaged (see also
parameter
21).
Y = closes if LOOP2 is clear
no = disabled
21
When this function is activated, and if parameter 20 is Y, the unit will wait for the opening
cycle to end before executing the closing command provided by LOOP2.
Y = closes at the end of
opening
no = disabled
22
When this function is activated: in case of a blackout, once electrical power has been resto-
red, if an OPEN command is not active the automated system recloses immediately.
Y = active
no = disabled
23
LOOP 1 commands opening and, once completed, it closes if disengaged (useful in case of
vehicle backing-up with consecutive loops). If disabled, when LOOP 1 is disengaged, it does
not close.
Y = closes if LOOP1 clear
no = disabled