EasyManua.ls Logo

FAAC S450H - 6 Bleeding

FAAC S450H
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
FAAC Model S450H 24V Hydraulic Swing Gate Operator
b
a
6. BLEEDING
2. Remove the screw in Fig. 24 ref.d from the front tting
3. Remove the joint (Fig.24 ref.f) from the operator stem.
(Fig. 24 ref. g).
1. Loosen the tie-rods (Fig. 23 ref. a) and remove the metal
protective housing (Fig. 23 ref. b).
Remove the upper tie-rod and be careful with the
O-ring that must remain it its seat.
4. Remove all spacers, if present (Fig. 25).
5. Tilt the operator upward as much as possible. Do not force
the rear tting too much.
6. Supply the operator with power and repeatedly move the
stem in and out, over its complete stroke, until reaching a
smooth movement (Fig. 27).
7. After bleeding, repeat the operations described above in
reverse order.
TO PREVENT OIL LEAKAGE FROM
THE BREATHER HOLE, DO NOT TILT THE
OPERATOR DOWNWARD
Fig.23
d
f
g
Fig.24
Fig.26
Fig.25