EasyManua.ls Logo

Faber BF110V/Straight - Page 35

Faber BF110V/Straight
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UK/IRL
> > > > 35
3. Check if the measured pressure is the same as the prescribed pressure;
4. Perform this measuring when the appliance burns on full capacity and when only the
pilot ignition burns;
5. When the pressure is too low, check if the gas pipes are made of material wit the right
diameter;
6. When the pressure is too high (more than 5 mBar) you can’t install the appliance and
you should contact your gas company;
7. Always check the burner pressure when the functional pressure is right.You can measure
the burner pressure by using sensor D.The pressure should match the prescribed
pressure. If this is not the case, then contactn the supplier.
Note:
After checking the burner pressure, the Inlet pressure test point has to be shut and
checked for gas-tightness.