33EN
grindercontrol.
Presstheicon
.
Exampleofinformationontheowsofeachsingle
dispensingsenttothePlat-OneplatformviaWIFI.
(A)GR1singlecoffee,
(B)GR3doublecoffee,
(A/B)GR2centralwithonesinglecoffeeandonedouble,
(C)thelterholderisnotusedforspecialcoffees.
Grinder control parameters conguration
Toincreaseordecreasethemeasure-timeoperateasfollows:
1)pressthe
iconfromthemainscreen:
2)Thefollowingisdisplayed:
USER MENU
DOSING
COUNTERS
MODALITY
3)presstheDOSINGitem;thefollowingisdisplayed:
DOSING
DOSE 1
DOSE 2
DOSE 3
4) select the measure to be modied; the following is
displayed:
CHANGE DOSE 1
02.25
Change the value by the +” and -” icons; conrm the
enteredvaluebythe
iconorpressthe iconto
leaveitunchanged.
Themeasure-numbercorrespondenceisthefollowing:
DOSE 1 forthesinglemeasure
;
DOSE 2 forthedoublemeasure
;
* DOSE 3 forthecontinuousmeasure
Note: single-measure’s and continuous measure
grinding time variation in user mode is ± 25
hundredths of second (0 ÷ 1/4 second).
Double-measure’s
grinding time variation in
user mode is ± 50 hundredths of second (0 ÷ 1/2
second).
* Grinding in continuous mode, if equal to zero
(DOSE 3 = 0), can only be modied by the
technician.
Dose time variation relative to the MD3000 grinder/dispenser