SERVICE MANUAL
ADVANCE OVENS
04/02/2020 90
To display the version, press Humidifier, and view as follows:
DSI = [PPC]
DSD = [CVV]
DII = [GG]
To exit this mode, press Cool Down.
GAS TYPE (ONLY AGC)
As different types of gas are used (LPG B/P, NG) the Burner Fan Speeds should be adapted to obtain optimum
combustion. In this section select the gas to be used. Depending upon the model of oven and type of gas selected,
certain default values are established for the starting speeds, minimum and maximum power .
DSI = [OPT]
DSD = [OP12]
DII = [GAS]
DID = [BP] (Butane-propane) (Default setting)
[ NG] (Natural Gas)
[ GV] (City Gas)
START-UP SPEED OF CC BLOWER (ONLY AGC)
Option for changing the pre-established starting speed of the chamber blower. This value may range between 0 and
8000 in multiples of 10.
DSI = [OPT]
DSD = [O14]
DII = [SC1]
DID = [0 ÷ 800] (Default settings, see table of default speeds)
MEDIUM SPEED OF CC BLOWER (ONLY AGC)
Option for changing the pre-established minimum speed of the chamber blower. This value may range between 0
and 8000 in multiples of 10.
DSI = [OPT]
DSD = [O16]
DII = [mC1]
DID = [0 ÷ 800] (Default settings, see table of default speeds)
MAXIMUM SPEED OF CC BLOWER (ONLY AGC)
Option for changing the pre-established maximum speed of the chamber blower. This value may range between 0
and 8000 in multiples of 10.
DSI = [OPT]
DSD = [O17]
DII = [MC1]
DID = [0 ÷ 800] (Default settings, see table of default speeds)