Selection criteria
SELECTING CRITERIA
Power supply selection
5.
227
DDS
HARDWARE
Ref.1310
T. H5 /14 Selection of the mains connection cable.
POWER CABLE FOR MAINS CONNECTION
Vmains from 400 to 460 V AC Rated current through the mains cable
MAINS POWER
COMPACT AXIS DRIVES (ACD):
COMPACT SPINDLE DRIVES (SCD):
Power cable
In Amperes Reference
if C < 12.5 MPC-4x1.5
if C < 16.5 MPC-4x2.5
if C < 23 MPC-4x4
if C < 29 MPC-4x6
if C < 40 MPC-4x10
The purchase order must indicate the length of the cables
4
(kW)
* 1000 / (3 · Vmains)
=
A
C
RATED CURRENT ON FXM & FKM MOTORS
=
A
C
MAX. CURRENT ON FM7/FM9 MOTORS
=
A
C