Power supplies
94
2.
POWER SUPPLIES
Regenerative regulated power supplies
84
DDS
HARDWARE
Ref.1310
FAGOR supplies the right CHOKE RPS for this application. See the rele-
vant cable section in table T. H2/23. Note that the cable must be shielded.
The data for the RPS choke connection terminals is:
WARNING. Chokes are a must for the operation of a regenerative power
supply. Installing a choke with an inductance other than the one recom-
mended for a choke may cause severe damage to the unit.
T. H2/31 Data of the RPS choke connection terminals.
CHOKES RPS-75-3 RPS-45 RPS-20
Gap (mm) - - 10.16
Min/max tightening torque (N·m) 1520 6 1.5
Section (mm²) 70 35 10