EasyManua.ls Logo

Fagor AXD 1.08 - Page 89

Fagor AXD 1.08
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power supplies
POWER SUPPLIES
Regenerative regulated power supplies
2.
89
DDS
HARDWARE
Ref.1310
The next table shows the signals and other considerations related to each
pin of connector X6:
T. H2/37 Description of the pins of connector X6.
1 ERROR RESET
System error RESET input
(24 V DC; 4.5-7 mA).
2 N.C. Not connected
3 GND
0 volts reference for digital inputs.
Error RESET (1) and System Speed Enable (5).
4 PWM ENABLE
Safety.
Power bus voltage enable input (24 V DC).
5
SYSTEM SPEED
ENABLE
General system speed enable.
(24 V DC; 4.5-7 mA).
6 SYSTEM OK
Contact indicating module status. It opens in case
of failure. Limit 1 A at 24 V.
7 SYSTEM OK

Related product manuals