02/05/2020 32
SERVICE MANUAL
CONVEYOR BELT
water inlet hose to A+F.
• Install a shut-off valve on the water supply close to the machine in an accessible position.
• A filter must be installed after the shut-off valve and before the appliance and should be easily accessible
for cleaning.
• Check that the mains pressure is within the range indicated above.
• Check that there are no leaks.
The hydraulic circuit guarantees a stable consumption in the event of changes in pressure in the mains. The water
input pressure to the machine should be 2 to 4 bar. Therefore, the rinse water control pressure must be adjusted to the
following pressures:
CCO-120 -> 0.7 bar -> 210 L/h
CCO-160 -> 0.9 bar -> 240 L/h
CCO-180 -> 0.7 bar -> 210 L/h
CCO-225 -> 0.7 bar -> 210 L/h
CCO-270 -> 0.9 bar -> 240 L/h
CCO-320 -> 0.9 bar -> 240 L/h
In the ECO models, the rinse water flow must be adjusted with the following flows:
CCO-120 ECO -> 210 L/h
CCO-160 ECO -> 240 L/h
CCO-180 ECO -> 210 L/h
CCO-225 ECO -> 210 L/h
CCO-270 ECO -> 240 L/h
CCO-320 ECO -> 240 L/h
19.5. WATER CONSUMPTION