02/05/2020 64
SERVICE MANUAL
CONVEYOR BELT
DISHWASHERS
34.4.1. FREQUENCY VARIATOR PARAMETERS
To access the frequency variator parameters, press P. To exit this option, press Pagain. If any of the Basiclevel
values are modified, level
3must be programmed again.
The frequency variator is configured at the factory and has different settings depending on the model of the machine.
12167527 Frequency variator programmed CCO-120 and CCO-120 ECO
12167528 Frequency variator programmed CCO-160 and CCO-160 ECO
12167529 Frequency variator programmed CCO-180 and CCO-180 ECO
Parameter Definition
Value:
CCO-120 +
CCO-120
ECO
CCO-160 +
CCO-160
ECO
CCO-180 +
CCO-180
ECO
CCO-225
+
CCO-225
ECO
CCO-270
+
CCO-270
ECO
CCO-320
+
CCO-320
ECO
P0010
Start
programming
1 1 1 1 1 1
P0100
Value in kW 50
Hz
0 0 0 0 0 0
P0304
Vn (V)
230
230
230
230
230
230
P0305
IN (A)
1.4
1.4
1.4
1.4
1.4
1.4
P0307
PN (kW)
0.27
0.27
0.27
0.27
0.27
0.27
P0310
Fn (Hz)
50
50
50
50
50
50
P0311
rpm (Nom)
1395
1395
1395
1395
1395
1395
P0700
Terminal
2
2
2
2
2
2
P1000
ADC setting
2
2
2
2
2
2
P1080
F. Min. (Hz)
20.0
23.8
21.4
29.8
33.3
40.5
P1082
F. Max. (Hz)
28.6
38.1
42.9
53.6
64.3
76.2
P1120
Time ON (s)
5
5
5
5
5
5
P1121
Time OFF (s)
0
0
0
0
0
0
P3900
End
programming
and recording
data
1 1 1 1 1 1
P0003
Expert level
3
3
3
3
3
3
P0005
Output current
display
27 27 27 27 27 27
P0611
Overload
activation time
(seconds)
1216 1216 1216 1216 1216 1216
P0640
Current
overload (%)
150 150 150 150 150 150
P1210
Automatic
restart
6 6 6 6 6 6
P1300
Lineal mode
(V/f)
0 0 0 0 0 0
P1800
Base f. Khz
16
16
16
16
16
16
P2000
Setting
reference f. Hz
52 68 72 90 106 129
Average
frequency (Hz)
23.8 31 32.1 41.7 48.8 58.3

Table of Contents