Hardware configuration
CNC 8065
9.
(REF: 1404)
·93·
EMERGENCY BATTERY.
9 EMERGENCY BATTERY.
The emergency battery ensures the operation of the central unit against power failures and,
if necessary, allows the CNC to execute the automatic shut-down sequence due to a power
failure.
General characteristics.
Charge time. 35 hours.
Autonomy. About 20 minutes with the battery completely charged.
Work temperature. Between 5 ºC ( 41 ºF) and 40 ºC (104 ºF).
Read the connection instructions carefully before connecting the battery. Connect the battery only to
the central unit; DO NOT try to power any other device with the battery. Recharge the battery only
through the central unit; DO NOT try to recharge it with any other device.
Do not through the battery into the fire. Do not short-circuit the pins of the battery.