EasyManua.ls Logo

FAS PERLA HP - Setting the Temperature Parameters

FAS PERLA HP
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34 PERLA HP - ISSUE 02
FAS International S.p.A. - Via Lago di Vico, 60 - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
Command 10 Displays totals clearable:
This command has the same functions as command 09, but it can be cleared through command 92.
Command 11 Setting the selection sequences :
The function of this command is to set the dispensing of the same type of product in order to obtain a
uniform and progressive emptying of the tray, irrespective of the customer’s choice.
Initially the command asks the operator to enable (option 1) or disable (option 0) the function.
If the option is active (1) the system asks the operator to enter the first selection that forms the sequence,
then asks the operator to assign a product code and price. Confirm each time by pressing ENTER. Add the
remaining selections that are part of the same sequence . Press ESC to conclude and confirm the first
sequence. At this point, another sequence may be entered, or exit the command by pressing ESC a second
time.
This option is only available on SLAVE vending machines.
10.2.2 SETTING THE TEMPERATURE PARAMETERS
Command 41 Set the temperature:
Espresso Vending Machine: This command allows you to adjust the working temperature of the boiler. The
predefined value is 95°C, but it may vary from 70°C to 120°C. The machine requires the temperature
differential, a value which is added to the boiler's working temperature to compensate the heat loss of the
selected beverage caused by the dispersiveness of the dispensing system after a period of inactivity. This
value is predefined at +15°C.
N.B.: The sum of the above values must not exceed 120 °C.
If the slave machine is enabled, a request appears asking the internal temperature of the connected snack
machine be set: the preset value is +3°C, and can vary between +3 and +25°C.
Instant Vending Machines: This command allows you to adjust the working temperature of the boiler. The
predefined value is 91°C, but it may vary from 70°C to 120°C. The machine requires the temperature
differential, a value which is added to the boiler's working temperature to compensate the heat loss of the
selected beverage caused by the dispersiveness of the dispensing system after a period of inactivity. This
value is predefined at 0°C.
N.B.: The sum of the above values must not exceed 120 °C.
If the slave machine is enabled, a request appears asking the internal temperature of the connected snack
machine be set: the preset value is +3°C, and can vary between +3 and +25°C.
Command 44 Set the defrosting frequency: (only slave machine)
This command sets the defrosting frequency expressed in hours, that is, the time between one defrosting
cycle and the next. The preset value is for 4h but can vary between 2h and 8h.
Command 45 Setting the cut-out duration for the refrigeration safety device:
(only slave machine)
This command sets the amount of time that the refrigeration safety device is to remain disabled. This period
of time prevents the vending machine from shutting down following an operation that involves having the
door open with the subsequent increase in the internal temperature. The delay in activating the refrigeration
unit safety device gives the machine time to return to its normal operating temperature. The value of this
command is preset at 60 min. but can be varied from 30 to 360 min.

Table of Contents