SUB-CODE FAILURE
102 /
Waste Level
103 /
Low Water Level
104 /
Cup Holder Empty
105 /
Cup movement error
106 /
Sugar-stirrer dispenser
107 /
Coffee unit jammed in open pos. (CRG micro does not close)
108 /
Coffee metering unit doser
109 /
Coffee unit does not reach closed pos.(CPP micro does not close)
110 /
Coffee dispensing timeout (volumetric meter)
111 /
Coffee unit does not reach open pos. (CRG micro does not open)
112 /
Grinding timeout
113 /
Coffee unit not installed
114 /
Cup dispenser with photocell error
115 /
Faulty pressure boiler temperature probe
117 /
Instant dispensing timeout (volumetric meter)
118 /
Error on unit opening microswitch (CRG microswitch bounce).
119 /
Cup dispenser micro does not close
120 /
Wrong dose.
121 /
Coffee unit opens while dispensing (CPP opens while dispensing in
progress)
122 /
Coffee unit jammed in closed pos. (CPP does not open)
123 /
Cup dispenser micro does not switch over
128 /
Sugar/stirrer dispenser (CDZP micro does not close)
129 /
Sugar/stirrer dispenser (CDZP micro does not open)
130 / Payment system out of service.
131 /
Timeout beverage execution (dispensing time exceeded).
10 / Internal temperature feeler faulty
16 (*) 33 - 36 – 39 Error communication with peripheral (a board for the electric panel)
17 (*) 39
Communication break during sale cycle without credit collection
18 (*) 39
Communication break during sale cycle with credit collection
20 (*) 39
Opening door lock error
21 (*) 39
Closing door lock error
31 (*) 39
Photocell test error .
32 (*) 39
Photocell calibration error
51 (*) 39
Interruption of peripheral connection at the beginning of the sale cycle.
61
Number selection
code
Motor blocked (the spiral does not rotate) SLAVE
62
Number selection
code
The spiral does not complete the rotation SLAVE
64
Number selection
code
selection absent SLAVE
65
Number selection
code
Motor disconnected SLAVE
69
Number selection
code
Possible microswitch defect or spiral motor wiring defect SLAVE
(
*
)Key:
33 = Photocells
36 = Powerboard Perla HP
39 = Spirali Slave
10.2.4 TO SET MACHINE SLAVE PARAMETERS
Command 73 Enabling the photoelectric cells:
This command should be set at 1 only if the photoelectric cell system is installed. Its function is to
enable=1/disable=0 this device. Set the command at 1 (photocells enabled), to automatically access the
menu which allows this function to be disabled if necessary for the desired selections (delivery without
photocell control). To disable the option corresponding to one or more selections, simply key in the selection
number and then set the value at zero.