Questions and Answers

  • J
    Jacqueline GarciaSep 1, 2025
    What to do if my FBD Beverage Dispenser shows Error #390: No ADA Keypad Detected?
    • D
      Debra CollinsSep 1, 2025
      If your FBD Beverage Dispenser displays Error #390 indicating 'No ADA Keypad Detected', it means the ADA keypad is missing, disconnected, or damaged. To resolve this: * Ensure the ADA keypad has no visible damage. * Ensure the keypad connector is plugged in correctly, making sure that the arrows on each connector align. * Replace the keypad if faulty.
  • W
    William LongAug 31, 2025
    What to do if my FBD Beverage Dispenser displays Error #111, 112, 113, 114: Motor Failure?
    • S
      Susan TannerAug 31, 2025
      If your FBD Beverage Dispenser displays Error #111, 112, 113, 114 indicating 'Motor Failure', it means the beater motor is not operating. To solve this: * Run a beater circuit diagnostic to determine the problem or refer to error #58X in this manual. * Check to make sure the beater motor is plugged in.
  • A
    Anita MccallAug 30, 2025
    What does error #081, 082, 083, 084: High Barrel Pressure on the FBD Beverage Dispenser mean?
    • J
      Jacob PattonAug 30, 2025
      Error #081, 082, 083, 084 'High Barrel Pressure' on the FBD Beverage Dispenser indicates that the pressure on a barrel exceeded 55 PSIG (379 kPag). Here’s how to address it: * Dispense a drink to reduce the barrel pressure. The dispenser will refreeze if set to the ON mode. * Run the fill diagnostic if a failed component is suspected. * Check the 'Active Charge' regulator located on the product header to ensure it is set at 30 PSIG (207 kPag). All barrels should be fully depressurized before checking the active charge.
  • N
    nicole44Aug 29, 2025
    What does error #270: Air Out mean on my FBD Beverage Dispenser and how do I resolve it?
    • B
      Becky BellAug 29, 2025
      Error #270 'Air Out' on your FBD Beverage Dispenser indicates that the compressed air pressure is less than 45 PSIG (310 kPag). To resolve it: * Verify there is a supply of compressed air. * Ensure the compressed air shutoff valve at the back of the dispenser is not turned off. * Ensure the gas pressure transducer is connected and working properly. * Ensure the compressed air supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator if needed.
  • B
    Barry ChungAug 28, 2025
    What does error #280: N2 Out mean on my FBD Beverage Dispenser and how can I fix it?
    • K
      Karen RobertsAug 28, 2025
      Error #280 'N2 Out' on your FBD Beverage Dispenser indicates that the N2 pressure is less than 45 PSIG (310 kPag). To fix it: * Replace or refill the N2 tank. * Ensure the N2 shutoff valve at the back of the dispenser is not turned off. * Ensure the N2 pressure transducer is connected and working properly. * Ensure the N2 supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator if needed.
  • D
    Dorothy BaileyAug 27, 2025
    What does error #410: Gas #1 - N2 Out mean on my FBD Beverage Dispenser and how to solve it?
    • J
      Jeanne StewartAug 27, 2025
      Error #410 'Gas #1 - N2 Out' on your FBD Beverage Dispenser indicates that the nitrogen (N2) pressure is less than 45 PSIG (310 kPag). To solve it: * Replace or refill the N2 tank. * Ensure the N2 shutoff valve at the back of the dispenser is not turned off. * Ensure the N2 pressure transducer is connected and working properly. * Ensure the N2 supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator if needed.
  • J
    Jesse MorganAug 27, 2025
    What does error #430: Gas #2 - CO2 Out mean on my FBD Beverage Dispenser and how to solve it?
    • D
      david22Aug 27, 2025
      Error #430 'Gas #2 - CO2 Out' on your FBD Beverage Dispenser indicates that the CO2 pressure is less than 45 PSIG (310 kPag). To solve it: * Replace or refill the CO2 tank. * Ensure the CO2 shutoff valve at the back of the dispenser is not turned off. * Ensure the CO2 pressure transducer is connected and working properly. * Ensure the CO2 supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator if needed.
  • J
    Jose ReyesAug 25, 2025
    What does error #030: Water Out mean on my FBD Beverage Dispenser and how to fix it?
    • B
      Bruce MitchellAug 26, 2025
      Error #030 'Water Out' on your FBD Beverage Dispenser indicates that the water pressure is less than 45 PSIG (310 kPag). Here’s how to troubleshoot: * Ensure the water line to the dispenser is on and the water shutoff at the solution module is turned on. * Check that the gas supply line is connected to the water pump and the pump is not stalled. * Verify the gas supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator if needed. * Confirm the water pressure transducer is connected and working properly.
  • A
    Adrienne NewmanAug 25, 2025
    What to do if my FBD Beverage Dispenser displays error #020: CO2 Out?
    • P
      Patricia MichaelAug 25, 2025
      If your FBD Beverage Dispenser shows error #020 indicating 'CO2 Out', it means the CO2 pressure is less than 45 PSIG (310 kPag). To resolve this: * Replace or refill the CO2 tank. * Ensure the CO2 shutoff valve at the back of the dispenser is not turned off. * Make sure the CO2 pressure transducer is properly connected and functioning. * Verify the CO2 supply pressure at the dispenser is reading 70 PSIG (483 kPag), and adjust the regulator if needed.