15
SETTING AND WORK
In case of faults, contact the Assistance centre and provide the relevant code.
Error
code
Descripon
Shown on the indoor unit
display if:
Error
posion
Applies to:
immediately
procedure acvated
with remote control
200 seconds
aer the error
or immediately
if the procedure
was acvated with
remote control
Mono Split
Mul Split
Both
b0 Oil return procedure in cooling mode o outdoor o
b1 Protecon from cold air introducon in heang mode o indoor o
b2 Refrigerant recovery procedure o indoor o
CL Filter cleaning signal o indoor o
d0 Compressor frequency reducon for compressor over absorpon o outdoor o
d1 Compressor frequency reducon for unit over absorpon o outdoor o
d2 Compressor frequency reducon for high drain temperature o outdoor o
d3 Compressor frequency reducon for frost risk on the internal exchanger o outdoor o
d4 Compressor frequency reducon for unit overload o outdoor o
d5 Compressor frequency reducon for IPM overload o outdoor o
dF Defrost procedure or oil return in heang mode o indoor o
E0 Compressor drain temperature protecon o outdoor o
E1 General overheang protecon o outdoor o
E2 Compressor overheang protecon o outdoor o
E3 Internal exchanger an-freeze protecon o outdoor o
E7 Error on 4-way valve o outdoor o
E8 Protecon for abnormal external temperature o outdoor o
H0 Compressor blocked o outdoor o
H1 Compressor start error o outdoor o
H2 Over absorpon protecon on one compressor phase o outdoor o
H3 Compressor over absorpon protecon o outdoor o
H4 IPM module protecon o outdoor o
H5 IPM module overheang o outdoor o
H6 Protecon for current reading circuit to compressor error o outdoor o
H7 Error for compressor phase loss o outdoor o
H8 Error on the external fan motor o outdoor o
H9 Protecon for current reading circuit to external fan motor error o outdoor o
HE Auxiliary heater error o indoor o
L0 Indoor unit board jumper replacement error o indoor o
L1 Fault on the internal fan status reading circuit o indoor o
L2 Error on the external fan motor o indoor o
L3 Display of the communicaon error between Indoor and Outdoor unit o indoor o
L4 Communicaon port error o indoor o
L5 Indoor unit EEPROM memory module error o indoor o
L6 Display of the communicaon error between Indoor and Outdoor unit o outdoor o
LL Test procedure o indoor o
P0 Outdoor unit EEPROM memory module error o outdoor o
P1 Start error/electric charge circuit error o outdoor o
P2 Protecon for abnormal power voltage o outdoor o
P3 Protecon for too high supply voltage threshold o outdoor o
P4 Protecon for too low supply voltage threshold o outdoor o
P5 Protecon for direct-current voltage drop o outdoor o
P6 Unit overall current measuring circuit error o outdoor o
P7 Overcurrent protecon o outdoor o
P8 Current measuring circuit error on PFC module o outdoor o
P9 PFC module protecon o outdoor o
PC Incompable modes o outdoor o
U0 Internal air sensor fault o indoor o
U1 Internal exchanger sensor fault o indoor o
U2 External air sensor fault o outdoor o
U3 External exchanger sensor fault o outdoor o
U4 Cooling sensor 1 fault o outdoor o
U5 IPM module sensor fault o outdoor o
U6 Cooling sensor 2 fault o outdoor o
U7 External exchanger sensor fault o outdoor o
U8 Compressor drain sensor fault o outdoor o
ERROR DISPLAY
In case of errors during the unit operation, this condition will be displayed with a code identifying the system number
that triggered the error. Use the table below to understand the error codes.