Go to fetco.com for the latest versions of all information Page 12 User Guide & Operator instructions P213e0 NOVEMBER 2021
Brewer Usage, Water Filter Usage, and Statistics
ROLE: [LT]=Permanent total for lifetime of machine; [R]=operator resettable; [User]=Input needed from operator
G1-G4 are for water filter maintenance. All beverage equipment must use filtered water and filter cartridges must be monitored for quality
Resets all resettable counters to zero
G5 A, S, B Choose Counter Factory set to BASIC
Advanced=A
Stored brewer component activity..
See column 2, Counters, to identify where
G10-G15 Number of brews and volumes handled. Available in BASIC counter only (G5)
Dispensed volume Gallons/Liters Total of brews and hot water dispensed
Left side brew total
CBS-1252
Count Total brews-Left side (CBS-1252 only)
Right side brew total
CBS-1251&CBS-1252
Count
Total brews-Right side
CBS-1251&CBS-1252
G20-G55 component use cycles and volumes handled. Available in ADVANCED counter only (G5)
Hot water tank refill
cycles
Count Cycles of hot water tank refill
Total volume of water
for all brews
Gallons/Liters Quantity of water for brews
Left brew valve
operation on/off
Count
Totalized cycles of valve operation
(CBS-1252 only)
G26 A Lt Brew Volume [LT]
Left brew valve
flow through volume
Gallons/Liters
Totalized volume through left valve
(CBS-1252 only)
Right brew valve
operation on/off
Count
Totalized cycles of valve operation
CBS-1251&CBS-1252
Right brew valve
flow through volume
Gallons/Liters
Totalized volume through right valve
CBS-1251&CBS-1252
Left bypass valve
operation on/off
Count
Totalized cycles of valve operation
(CBS-1252 only)
Left bypass valve
flow through volume
Gallons/Liters
Totalized volume through left valve
(CBS-1252 only)
Count Count
Totalized cycles of valve operation
CBS-1251&CBS-1252
Right bypass valve flow
through volume
Gallons/Liters
Totalized volume through right valve
CBS-1251&CBS-1252
Left brew basket lock
flow through volume
Count
Totalized cycles of brew basket lock
operation (CBS-1252 only)
Right brew basket lock
operation on/off
Count
Totalized cycles of brew basket lock
operation CBS-1251&CBS-1252
ON/OFF switching for
heating elements
Count Totalized cycles of heater switching
Total ON time for
heating element
Hour Totalized heater ON time in hours
G80-G91 See illustration below for batch button positions Available in STATISTICAL counter only (G5)
Menu button selection
and activation count
Count
Total brews-left side top button
(CBS-1252 only)
Menu button selection
and activation count
Count
Total brews-left side middle button
(CBS-1252 only)
Menu button selection
and activation count
Count
Total brews-left side bottom button
(CBS-1252 only)
Menu button selection
and activation count
Count
Total brews-right side top button
CBS-1251&CBS-1252
Menu button selection
and activation count
Count
Total brews-right side middle button
CBS-1251&CBS-1252
Menu button selection
and activation count
Count
Total brews-right side bottom button
CBS-1251&CBS-1252