Menu Features: Batch Parameters
The settings below are shown for the top batch on a single brewer top left button on a twin brewer.
See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches
POSITION Program Items Factory set Default
Programming Range
Increments
Notes
A1.10 Batch Volume
0.51 to 2.00 gal
1.93 to 7.57L
A1.10
Batch Volume
CBS-2153 only
0.51 to 2.66 gal
1.93 to 10.1L
A1.20 Brew Time 5:00 minutes 2:00 – 12:00 0.30
Default total brew time is 6:30
minutes
A1.30 Prewet Perc. 0% 0.00 – 25.0% 1%
Percentage of total brew
volume
A1.40
Prewet Delay
(Pause after prewet
completes)
0% [1:00 Min] [0:10 – 5:00] 1:00 min
The time between prewetting
and start of brew cycle.
This feature appears ONLY
A1.50 Bypass Percent
CBS-1251:10%
CBS-1252/3:15%
0% – 40% 1%
Diverts brewing water from
brew process
This is a
Safety
Drip Delay 1:30 mm:ss 0:30 – 6:00 Min.
Time that brew basket remains
locked during final drip-out
Drip delay remains “ON” for
1:30 minutes if STOP is
A2.00
BATCH
ENABLED
YES
(Active)
Middle and Bottom
batches A2,3,5,6
Batch
on or off
Batches may be individually
enabled, rewritten or
A2.10 Batch Volume
0.51 to 2.00 gal
1.93 to 7.57L
A2.10
Batch Volume
CBS-2153 only
0.51 to 2.66 gal
1.93 to 10.1L
A2.20 Brew Time 4.00 minutes 2:00 – 12:00 0.30
Default total brew time is 5:30
minutes
A2.30 Prewet Perc. 0% 0.00 – 25.0% 1%
Percentage of total brew
volume
A2.40
Prewet Delay
(Brew pause after
prewet completes)
0% [1:00 Min] [0:10 – 5:00] 1:00 min
The time between prewetting
and start of brew cycle.
This feature appears ONLY
A2.50 Bypass Percent
CBS-1251:0%
CBS-1252&3: 0%
0% – 40% 1%
Diverts brewing water from
brew process
This is a
Safety
Drip Delay 1:30 mm:ss 0:30 – 6:00 Min.
Time that brew basket remains
locked during final drip-out
Drip delay remains “ON” for
1:30 minutes if STOP is
A30
A30 YES -
(defaults to recipe
Middle and Bottom
batches A2,A3
Batch
on or off
Batches may be individually
enabled, rewritten or
Batch
Copy From Batch A90 A90 1 (1-6)
PULSE BREW note. FETCO CBS-1200V+ brewers are factory programmed to pulse 2 cycles per minute brew time
Changing the brew time only will increase the pulses but will not change the volume of brew water delivered
.