RESETTING TO FACTORY DEFAULTS
Resetting the device to factory defaults:
Reset procedure allows to restore the device back to its factory set-
tings, which means all information about the Z-Wave controller and
user conguration will be deleted.
1. Switch o the mains voltage (disable the fuse).
2. Remove the device from the wall switch box.
3. Switch on the mains voltage.
4. Press and hold the B-button to enter the menu.
5. Wait for the LED indicator to glow yellow.
6. Quickly release and click the B-button again.
7. After few seconds the device will be restarted, which is signalled
with the red LED indicator colour.
NOTE
Resetting the device is
not the recommend-
ed way of removing
the device from the
Z-Wave network. Use
reset procedure only
if the primary con-
troller is missing or
inoperable. Certain
device removal can
be achieved by the
procedure of remov-
ing described in “Add-
ing the device on
page 5.
i
#9: Resetting to factory defaults

Other manuals for FIBARO ROLLER SHUTTER 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FIBARO ROLLER SHUTTER 3 and is the answer not in the manual?

FIBARO ROLLER SHUTTER 3 Specifications

General IconGeneral
Device TypeRoller Shutter Controller
ProtocolZ-Wave
Radio ProtocolZ-Wave
Dimensions42.5 x 38.25 x 20.3 mm
Mounting Box RequirementsØ ≥ 50mm, depth ≥ 60mm
Protection ClassIP20
Maximum Load for AC Output4.2A
Max Transmit Powerup to 6 dBm
RangeUp to 50m (open space)
Operating Temperature0°C to 40°C
Z-Wave Frequency868.4 MHz EU
CompatibilityWorks with various Z-Wave and Z-Wave Plus certified devices
Radio Frequency868.4 or 908.4 or 921.4 MHz EU frequency band