SPECIFICATIONS
Power supply:
Rated load current:
Supported motor type:
Required limit switches:
Power consumption:
Operating temperature:
Operating humidity:
Active element:
For installation in boxes:
Radio protocol:
Radio signal power:
Radio frequency:
Range:
Dimensions (L x W x H):
Compliance with EU direc-
tives:
100-240V~ 50/60 Hz
4.2A for lamps and resistive loads
1.7A for motors with compensated
power factor (inductive loads)
single-phase AC motors
electronic or mechanic
up to 0.8W
0-35°C
10-95%RH without condensation
micro-gap relay switch
Ø ≥ 50mm, depth ≥ 60mm
Z-Wave (500 series chip)
EIRP up to 6dBm
868.4 or 869.8 MHz EU;
908.4 or 916.0 MHz US;
921.4 or 919.8 MHz ANZ;
869.0 MHz RU;
up to 50m outdoors
up to 40m indoors
(depending on terrain and building
structure)
42.5 x 38.25 x 20.3 mm
RoHS 2011/65/EU
RED 2014/53/EU
#16: Specications