ADVANCED PARAMETERS
157. Time of down movement
This parameter determines time needed for roller blinds to reach the
bottom
.
For modes with positioning value is set automatically during calibra-
tion, otherwise it must be set manually.
Available settings: 1-90000 (0.01 - 900.00s, every 0.01s) - move-
ment time
Default setting: 6000 (60s) Parameter size: 4 [bytes]